Parker ViX Replacement Options

Corey Foster || Valin Corporation

Parker ViX Replacement OptionsFor many applications that are currently using Parker’s old ViX drives and controller/drives, AllMotion’s EZ controller/drives may be a great update path.  The ViX series was discontinued in March 2024.  While the ViX had some unique features, such as CANopen, an 80VDC input, and brake output, most applications didn’t need them, which makes AllMotion’s smaller products probable options.  The ViX also had a little bit higher motor current available and more I/O.

Both series have servo and stepper options with similar programming architecture options making the AllMotion products easily adaptable to the existing ViX applications. A great place to start for the servos is AllMotion’s EZSV17WV. For the steppers, AllMotion’s EZHR23ENHC is a good start. Both can be used as just drives as well.

The ViX part numbers that were discontinued included controller/drives and drives in both the servo and stepper varieties.

 

Stepper

Servo

(Standard Resolution)

Servo

(High Resolution)

Controller/Drive

VIX250IM-DRIVE

VIX500IM-DRIVE

VIX250IE-DRIVE

VIX500IE-DRIVE

VIX250IH-DRIVE

VIX500IH-DRIVE

Drive

Controller/drives can be used as drives.

VIX250AE-DRIVE 

VIX500AE-DRIVE

VIX250AH-DRIVE VIX500AH-DRIVE

AllMotion

EZHR23ENHC

EZSV17WV

EZSV17WV

 

Comparison of the stepper specifications between them…

 

ViX(250/500)IM

EZHR23ENHC

Length (inches)

5.71

2.25

Width (inches)

1.65

2.25

Height (inches)

3.35

1

Motor

Stepper

Stepper

Voltage

24-80VDC

15-40VDC

Current (RMS)

2.8 / 15.6

5

Step Resolution

Up to 51,200 Step/rev

Up to 51,200 Step/rev

Communication

RS232 / RS485 / CANopen

RS485 / RS232 / USB

Feedback

Encoder Input =< 400 KHz

Encoder Input =< 4 MHz

Digtial Inputs

5

Up to 4 configurable

Digital Outputs

3

2 relay drivers

Analog In

12 bit +/-10V Control signal

Configurable

Analog Out

10-bit resolution

 

 

Controller or Step/Dir

Controller or Step/Dir

PC Interface

EasiV (up to WinXP)

EZ Commander (Any)

Programming

ASCII command strings
Short programs

More capable

ASCII command strings
Macro Style 
Short programs

Brake Output

2A dedicated

2A configurable

Daisy Chainable

Yes

Yes

Anti-Resonance

Yes

No

Encoder Output

Yes

No

 

Comparison of the servo specifications between them…

 

ViX(250/500)(I/A)(E/H)

EZSV17WV (higher-power optional)

Length (inches)

5.71

2.25

Width (inches)

1.65

2.25

Height (inches)

3.35

1

Motor

Servo

Servo

Voltage

24-80VDC

20-40VDC

Current (Cont)

2.5 / 5.0

 

Current (Peak)

7.5 / 15

1.4

Communication

RS232 / RS485 / CANopen

RS485 / RS232 / USB

Feedback

Encoder Input

=< 400 KHz / 2.5 MHz

Encoder Input

=< 4 MHz

Digtial Inputs

5

Up to 4 configurable

Digital Outputs

3

2 relay drivers

Analog In

12 bit +/-10V Control signal

Configurable

Analog Out

10-bit resolution

 

 

Controller or Step/Dir

Controller or Step/Dir

PC Interface

EasiV (up to WinXP)

EZ Commander (Any)

Programming

ASCII command strings
Short programs

More capable

ASCII command strings
Short programs

Brake Output

2A dedicated

No

Daisy Chainable

Yes

Yes

Encoder Output

Yes

No

 

Comparison of some of the basic commands…

ViX

EZ

1GH
1R(ST1)

Homing Routine

/1Z###R

Homing Routine up to ### steps

1V##

Set Velocity

/1V##R

Set Velocity

1A##

Set Acceleration

/1L##R

Set Acceleration

1MA

Absolute Positioning

/1A##R

Absolute position move

1D##

Set Target Distance

/1D##R

Relative position move

1G 

Execute Move

 

 

1S

Stop 

/1n0$

Halt

EXAMPLE

1MA 1V100 1A10

1D1000 1G

Can be on one line with spaces or separate lines.

EXAMPLE

/1L10V100A1000R

Execute Absolute Move to 1000 with a speed of 100 and an acceleration of 10

 

Download Parker ViX Series Servo & Stepper Drive/Controllers Datasheet

Need another option? Ask a Motion Control Engineer