E2F & E2X Explosion-Proof Pressure Transducer from Ashcroft

E2F & E2X Explosion-Proof Pressure Transducer from Ashcroft
The Ashcroft® E2F and E2X pressure transducers fulfills a wide spectrum of pressure sensing requirements when explosion or flameproof hazardous approvals are required.  Using Ashcroft’s proven CVD thin film sensor technology provides a reliable and repeatable sensor manufactured to Ashcroft’s TruAccuracy terminal point standard.  The Ashcroft’s straight forward TruAccuracy standard eliminates confusion from statistically derived accuracy specifications and avoids the need for user calibration at the time of installation.  This makes the E2X and E2F ideal for demanding hazardous industrial and process applications.


E2F & E2X Explosion-Proof Pressure Transducer Features:

  • Uses Ashcroft’s proven CVD thin film technology
  • +/-0.25%, +/- 0.50% or +/-1.0% of span accuracy available
  • Standard ranges from vacuum to 20,000 psi and 0 to 500 psia (custom ranges available)
  • Rugged 316 stainless steel Housing
  • Diaphragm available in 17-4 PH, 316L stainless steel or A286
  • E2X – FM, CSA, ATEX and IECEx dual flameproof/ intrinsically safe approvals
  • E2F – FM, CSA ATEX and IECEx flameproof approvals
  • FM and CSA non-incendive approvals
  • 4-20mA or multiple Voltage outputs available
  • External magnetic offset and span adjustment
  • CE approved
  • RoHS compliant



E2F & E2X Explosion-Proof Pressure Transducer Applications:

  • Industrial and OEM Applications:
    • Oil Field Equipment
  • Process Applications:
    • Upstream Oil and Gas Production
    • Natural Gas Compression and Transfer Control
    • Alternative Energy
    • Engine Monitoring
    • Process & Pneumatic Sensing
    • Hydrogen applications



E2F & E2X Explosion-Proof Pressure Transducer Specifications:

Reference Temperature21°C ±2°C (70°F ±3°F)
Accuracy±0.25%, ±0.5%, ±1.0% of span Terminal Point Method includes: hysteresis, non-repeatability, zero offset and span setting errors
Stability≤±0.25% span/year at reference conditions
Durability>10 million cycles
Pressure RangesVacuum to 20,000 psig, 0 to 500 psi absolute
Ingress Rating
  • IP66
  • IP67
  • IP69K (consult factory)
Outputs
  • 0-10 Vdc (3 Wire)
  • 0-5 Vdc (3 Wire)
  • 0.1-10 Vdc (3 Wire)
  • 0.1-5 Vdc (3 Wire)
  • 0.5-4.5 Vdc (3 Wire)
  • 1-11 Vdc (3 Wire)
  • 1-5 Vdc (3 Wire)
  • 1-6 Vdc (3 Wire)
  • 20-4 mA (2 Wire)
  • 4-20 mA (2 Wire)
Wetted Material
  • Diaphragm: 17-4PH Stainless steel, 316L Stainless steel, 316L Stainless steel liquid isolated, A286
  • Process Connection: 316L Stainless Steel
Non-Wetted MaterialsHousing: 316L Stainless steel
Process Connection
  • 1/4 NPT Male
  • 1/8 NPT Male
  • ½ NPT Female
  • ½ NPT Male
  • ½-14 NPT Female
  • ¼ NPT Female
  • ¼˝ VCR gland with 9⁄16-18 Female Swivel Nut
  • ¼˝ VCR gland with 9⁄16-18 Male Swivel Nut
  • ¼-18 NPT Female
  • 1⁄8 -27 NPT Female
  • 7⁄16-20 UNF-2B SAE J1926
  • 7⁄16-20 UNJF-2A SAE Male (SAE J1926 O-Ring Boss seal)
  • 7⁄16-20 UNJF-3A 37° Flare (SAE AS4395)
  • 9⁄16-18 UNF-2B Female
  • G1/4 A-MALE (stud end DIN 3852-E G¼)
  • G½ B Male (EN837-1)
  • G¼ B-Male (EN837-1)
  • Sanitary Seal 1.5˝ Tri-Clamp®
  • Sanitary Seal 2˝ Tri-Clamp®
Shock & Vibration Resistance
  • 10g RMS 20-20,000Hz Vibration
  • 80g, 6ms Haversine Shock


Download Ashcroft E2X-E2F Explosion-Proof Pressure Transducer Datasheet


Contact us at (855) 737-4714 to learn more, or fill out our online form.
Process Control
A lesson for me is that I need to involve you earlier in the program.

You were tireless in your support and it will not be forgotten!

Valin Was There For Us
When we needed technical assistance and applications support, Valin was there for us. Their knowledgeable engineers saved us an invaluable amount of time, helping us get up and running quickly. We are very happy with their services.