Mitsubishi Electric PowerGate ‘H’ HVAC Bypass Controller

PowerGate ‘H’ Series HVAC Controllers offer the simplicity and functionality of an HVAC bypass controller and the high specification, performance and reliability of the Mitsubishi Electric FR-F800 VFD. The ‘Slimline’ enclosure is ideal for mounting in areas where space is limited. PowerGate ‘H’ is fully compatible with earlier generations of Mitsubishi Electric controllers and offers significant product advantages that allow it to meet the requirements of the most demanding applications.

PowerGate ‘H’ HVAC Bypass Controller Benefits

  • Mitsubishi Electric PowerGate ‘H’ HVAC Bypass Controller
    3 contactor bypass available in 230 V, 480 V, and 575 V in ‘Slimline’ and standard configurations 1 hp through 250 hp
  • NEMA 1 enclosure, 65 kA SCCR as standard
  • Plenum Rated
  • Manual or automatic bypass control
  • Electronic (pictured) or simple changeover versions
  • Dual independent PID control loops
  • Real-time clock feature and alphanumeric keypad display (S4 option)
  • Built-in BACnet® MS/TP communications
  • Bi-directional coasting motor restart (anti-windmill) capability
  • Broken belt / load abnormality detection
  • Anti-jam system to clear clogged pumps
  • Upload / download parameters using simple memory stick
  • Compatible with IPM motors (auto-tuning)
  • Motor flux control system saves energy and reduces motor heat and mechanical noise
  • Connects directly to FR-Configurator2 commissioning software


3 Contactor Bypass System

PowerGate H uses a 3rd bypass contactor to ensure that the drive is completely disconnected from the circuit when used in bypass mode, making it simple to remove the drive for service.


Anti-Windmill Feature (Coasting Motor Restart)

The drive will detect a motor already spinning in either direction on start-up, and ensure a smooth start-up every time.


65kA Short Circuit Rating

Controllers use coordinated contactors to ensure that they can safely be installed in areas served by large supply transformers (drives have a 100kA withstand rating).


Broken Belt Detection (Load Memory System)

The new ‘load memory’ system detects any sudden changes in load, such as a broken belt or a clogged pump.

Download Mitsubishi Electric PowerGate ‘H’ HVAC Bypass Controller Flyer

Talk to one of our experts today at (855) 737-4716, or fill out our online form to learn more.

 

Motion Control and Automation
A lesson for me is that I need to involve you earlier in the program.

You were tireless in your support and it will not be forgotten!

Valin Was There For Us
When we needed technical assistance and applications support, Valin was there for us. Their knowledgeable engineers saved us an invaluable amount of time, helping us get up and running quickly. We are very happy with their services.