Series DRCS Drives from Camozzi Pneumatics

Series DRCS Drives from Camozzi Pneumatics
 

Series DRCS drives can calculate the normal resonance frequency of the motors and optimize their performance. The availability of eight inputs allows the realization of a table of 127 commands, for each of which it is possible to set position, speed, acceleration, and deceleration.

Each command can be absolute or relative. Through the Step and Direction commands, it is possible to control the drive in frequency mode. The frequency defines the speed, while the number of steps defines the position. The Series DRCS drives are equipped with serial protocols CANopen CiA 301 and CiA 402 through which it is possible to perform motion control and condition monitoring of the drive. To configure the drive, wired USB 2.0 or WLAN connections can be used.
Thanks to an innovative system that takes advantage of Near Field Communication (NFC) technology, it is possible to extract production and statistical data on the use of the drive, which are essential parameters for industry 4.0.

 

Series DRCS Drive Benefits

  • Full digital drive with integrated PLC functions
  • Programmable with the Camozzi QSet configuration software
  • Feedback by incremental encoder
  • NFC (Near Field Communication) system enabled
  • 127 programmable positions (setting, acceleration, speed, and position)
  • Wire configuration by means of USB 2.0 and WLAN BL-BLE
  • Can be controlled in frequency (step and direction), digital I/O, and serial CANopen protocol


Series DRCS Drive Specifications

  • Logic: 18 ÷ 32 V DC
  • Power: 24 ÷ 60 V DC
  • Current:  0.1 ÷ 7 A
  • Holding Current:  Automatic reduction of the holding current with the motor in stop mode, this function can be set according to the holding current or its delay
  • Operating Temperature: 0 ÷ 40°C (up to 55°C with forced ventilation)
  • Storage Temperature:  -20°C ÷ 70°C
  • Humidity: 0 ÷ 90%
  • Altitude: < 1000 meters
  • Vibration: 1G (10 to 500 Hz)
  • Protection: Overvoltage, minimum voltage, overtemperature, short-circuit, or grounding on the motor
  • Control Method: 4 state PWM 20kHz
  • Amplification Type:  Dual H-Bridge, 4 Quadrants
  • Position Control Encoder: 100 to 5000 differential impulses/revolution
  • Input Control Signal: 12 opto-isolated 24 V DC
  • Output Control Signal: 6 opto-isolated
  • Input Impulse Control: Step inlet and frequency direction maximum 10kHz
  • Output Control Signal: Electromechanical brake max current 1A
  • USB: USB 2.0
  • WLAN: BL-BLE
  • RFID: with NFC devices
  • CANopen: CiA 301 and CiA 402 (interpolated position mode)
  • Microstep Emulation: High resolution by means of microstepping and detailed synchronization. Reduction of oscillations and of resonance vibrations
  • Anti-Resonance: Activation of the oscillation system in order to reduce vibrations and obtain a smooth movement, control of speed, and a reduction of the time of oscillation
  • Led Status: green led
  • Configuration: Digital with the Camozzi QSet configuration software
  • Control Methods: Digital inputs | Frequency | CANopen
  • Data Retention Memory: Flash
  • Configuration Data Backup Memory: E2prom
  • Weight: 0.46 kg

     

Download Series DRCS Drives from Camozzi Pneumatics Datasheet 



Talk to one of our experts today at (855) 737-4716, or fill out our online form to learn more.

Short description