214 High-Flow Gas Shut Off Solenoid Valves from ASCO™

214 High-Flow Gas Shut Off Solenoid Valves from ASCO™
The ASCO Series 214, also known as 8214, high-flow, low-pressure (5 psi) gas safety shutoff valves are specifically designed for on-off control of fuel gas in commercial and industrial gas burners. Their unique double-disc design with over travel provides redundant sealing for leak-tight shutoff on pilot or main gas lines. A double-solenoid gas train provides an exceptionally small footprint for space constrained applications. The valves are ideal for natural gas fired boilers, furnaces, grain dryers, kilns, gas generators and commercial kitchen/cooking equipment.


214 High-Flow Gas Shut Off Solenoid Valves Features

  • Low pressure drop and extremely high flow capacity make the valve ideal in low gas supply pressure applications and locations
  • Visual indication of open and shut position meets NFPA and FM requirements for visual indication
  • Proof of closure switch meets agency/code requirements for an electrical interlock of valve closed position
  • 1/8-inch NPT pipe taps with plugs provide easier routine testing
  • Broad ambient range of -40?F to 140?F is ideally suited for frigid and hot environments
  • Optional NPT threaded flange adapters allow direct piping that simplifies installation and maintenance
  • Silicon-free constructions are available for painting/finishing applications
  • Most constructions available on ASCO SameDay or 5Day shipping program to keep production lines running smoothly



214 High-Flow Gas Shut Off Solenoid Valves Specifications

  • Valve Actuation: Solenoid
  • Body Material: Aluminum
  • Media: Air, Inert Gas, Liquid Propane Gas, Natural Gas, Oxygen
  • Pipe / Port Size: ¾ "; 1 "; ¼ "; ½ "; 2 "; ½ "; 3 "
  • Port Type: NPTF
  • Function: 2 way - 2/2 Normally Closed, 2 way - 2/2 Normally Open
  • Flow: From 6.0 Cv to 14.0 Cv;Over 14.0 Cv, From 5.19 to 12 Kv;Over 12 kv
  • Voltage: 110 AC;115 AC;12 DC;120 AC;120 DC;208 AC;220 AC;230 AC;24 AC;24 DC;240 AC;240 DC;440 AC;48 DC;480 AC;6 DC | 50/60
  • Max Differential / Max Operating Pressure: Hazardous; Indoor; Outdoor
  • Operating Environment: Hazardous, Indoor, Outdoor

Talk to one of our process control experts today at (855) 737-4714, or fill out our online form to learn more.
Process Control
A lesson for me is that I need to involve you earlier in the program.

You were tireless in your support and it will not be forgotten!

Valin Was There For Us
When we needed technical assistance and applications support, Valin was there for us. Their knowledgeable engineers saved us an invaluable amount of time, helping us get up and running quickly. We are very happy with their services.