LiquiPro™ FG Gas Cartridge Filters from Porvair

LiquiPro F2 All-PTFE Filters from Porvair 

LiquiPro F2 All-PTFE Filters from Porvair
LiquiPro F2 All-PTFE Filters from Porvair
LiquiPro™ FG is designed to remove particles from process and bulk gas filtration for flow rates up to 7000slpm (247scfm) per 10-inch cartridge filter. Made of high-quality PTFE media with low pressure drop, high flow rate and long service life.

 

LiquiPro™ FG Gas Cartridge Filters Features:

  • Proprietary expanded PTFE media used within the LiquiPro™ FG filter ensures a high-purity gas filter with a large surface area to ensure high flow rate and high dirt-holding capacity.
  • Certificate of quality enclosed with each product lot for quality assurance that ensures filter-to-filter and lot-to-lot performance.
  • Reuse, Reduce, Recycle. Customer may return LiquiPro™ FG for sterilization by autoclave at 121C and re-used up to 20 times. For filter sterilization request a certificate of decontamination must be completed and signed off by the customer.
  • Only for CDA, bulk and inert gas filters
  • MOQ 25-100pcs preferred
  • Additional flow-DP check service may be requested
  • Manufactured in a facility with class 1000 and 100 clean room with ISO9000 certification to ensure high-purity performance.


LiquiPro™ FG Gas Cartridge Filters Applications:

  • Flat panel manufacturing CDA, bulk and process gas applications.
  • Ultra-high-purity tank venting (to ensure sterility or contamination control).
  • Advanced wafer level packaging.
  • Photovoltaic water, chemical and gas applications.
  • Data storage industries


LiquiPro™ FG Gas Cartridge Filters Specifications:

  • Pore size rating
    • 0.01, 0.02, 0.1, 0.2, 0.5, 1.0, 5.0 and 10.0 m
  • Maximum differential pressure:
    • 4.1 bard (69.69 psid) @ 20°C (68°F)
    • 2.75 bard (39.83 psid) @ 60°C (140°F)
  • Compatibility and purity
    • Filters do not use any binders, surfactants and adhesives for broad usage compatibilities. Only 100% high purity virgin polypropylene is used.
  • Materials of construction
    • Filter media: PTFE membrane
    • Support: Polypropylene
    • End caps, core, cage: Polypropylene
    • O-rings: EPDM, FKM and E-FKM
  • Recommended change-out differential pressure
    • 1bard (14.5 psid)
  • Maximum operating temperature
    • 70°C (158°F)

 

Download Porvair LiquiPro FG Gas Cartridge Filters Datasheet 



Talk to one of our filtration experts today at (855) 737-4717 or fill out our online form to learn more.

 

Short description

Designed to remove particles from process and bulk gas filtration.