Created exclusively for use in Chemical Mechanical Planarization (CMP) tools, the patented Malema Interconnect Interlock Device (MIID-1000) By-Pass Leak Detection and Prevention System, has been designed specifically to protect against liquid back-flow and internal bypass leaks. This capability is created via a manifold of pneumatically actuated valves that operate in a coordinated fashion in order to ensure that CMP-liquid supplies cannot be contaminated before use or during the actual CMP process. MIID-1000 has retrofit kits that can be installed into existing CMP tools.
MIID-1000 Malema Interconnect Interlock Device Features
- All high purity PTFE and PFA construction of the wetted components.
- Non-wetted surfaces of PFA and PVDF
- Integrated design for compact, space savings installation.
- Designed for minimal head loss
- Field configurable flare connections [Inlets can be configured as either ¼” or 3/8” flare nipples] allowing for simplified retrofit installation and reduced inventories
- Valve components tested to over 10,000,000 cycles in DIW (over 1,050,000 in Cabot SS-12).
- Valve Cv = 0.8
- Built-in leak detection & monitoring
- Built-in optical valve position sensing
MIID-1000 Malema Interconnect Interlock Device Specifications
Media pressure | 0 to 80 PSIG 0 to 5.5 Bar |
Pneumatic actuation pressure | 60 to 120 PSIG 4.1 to 8.3 Bar |
Media Temperature | 0°F to 266°F (excluding phase changes) -17.7° C to 130° C |
Ambient Temperature | 0°F to 150°F (no freezing liquids) -17.7° C to 65.5° C |
Wetted Surfaces | PFA & PTFE(modified) |
Non-Wetted Surfaces PFA, PVDF | - Other Materials: Viton Seals, Halar Coated Stainless, Stainless Steel, Polypro, Nylon, Acetyl,
- Mounting: Mount the MIID horizontally with the Drain Outlet facing UP.
- Mounting: Two(2) 10-32 screws required but, not provided
- Pneumatic control interface: 10-32 UNF-2B (M5)
- Electrical interface: 24 VDC, 0.1 A max
- Critical Valve characteristic: Cv = 0.8
- Inlets: Field Configurable as ¼” or 3/8” Flare nipple
|
POU Outlet | ¼” Flare nipple |
Vent-Drain Outlet | 3/8” Flare nipple |
Overall Dimensions (each MIID block) | o Height 5.50” 139.70 mm
o Width 3.75” 95.25 mm
o Length 6.50” 165.10 mm |
Overall Dimension (Three(3) MIID Kit) | o Height 5.50” 139.70 mm
o Width 11.25” 285.75 mm
o Length 6.50” 165.10 mm |
Overall Dimensions (PLC Module) | o Height 2.75” 70.00 mm
o Width 3.68” 93.00 mm
o Length 6.31” 160.00 mm |
Download Malema MIID-1000 Malema Interconnect Interlock Device Datasheet Talk to one of our process control experts today at
(855) 737-4714, or fill out our
online form to learn more.