The 2300 Series Industrial Self-Regulating Heating Cable is designed to provide reliable freeze protection and process temperature maintenance for industrial piping, fluid transport systems, and storage equipment exposed to cold temperatures or demanding operating conditions. Its self-regulating technology automatically adjusts heat output in response to local temperature changes, helping deliver heat where it is needed. Designed for industrial environments, the 2300 Series supports continuous temperature maintenance up to 250°F (120°C), withstands intermittent temperature excursions up to 366°F (185°C), and can tolerate 150 psig saturated steam purging under specified conditions. Field-cuttable cable lengths and configurations for ordinary and certain hazardous locations make it a versatile solution for industrial heat tracing applications.
Features
2300 Series Industrial Self-Regulating Heating Cable Features
- Self-regulating heat output: Automatically adjusts heat output in response to local temperature variations along the cable.
- High-temperature performance: Maintains process temperatures up to 250°F (120°C) under specified operating conditions.
- Intermittent high-temperature resistance: Withstands intermittent temperature excursions up to 366°F (185°C).
- Steam-purge capability: Designed to withstand 150 psig saturated steam purging under specified conditions.
- Field-cuttable design: Can be cut to the required length and terminated in the field using approved accessories and installation procedures.
- Overlap tolerance: Designed not to overheat or burn out when overlapped, subject to the manufacturer's installation requirements.
- Multiple heat-output options: Available in configurations including 5, 10, and 15 watts per foot at 50°F, depending on the model.
- Multiple supply voltages: Available in configurations for 110–120 VAC and 208–277 VAC, depending on the model.
- Industrial environment compatibility: Available with conductor, braid, and jacket configurations intended for different environmental and installation requirements.
- Hazardous-area options: Certain configurations are approved for specified hazardous (classified) locations. The exact cable construction and approval must match the area classification and application.
Specifications
2300 Series Industrial Self-Regulating Heating Cable Specifications
| SPECIFICATION | 2300 SERIES |
|---|---|
| Product Type: | Industrial self-regulating electric heat trace cable |
| Heat Output: | 5, 10, and 15 W/ft at 50°F, depending on model |
| Supply Voltage: | 110–120 VAC or 208–277 VAC, depending on model |
| Maximum Continuous Maintenance Temperature: | 250°F (120°C) |
| Maximum Intermittent Temperature Excursion: | 366°F (185°C) |
| Steam-Purge Resistance: | 150 psig saturated steam purging, under specified conditions |
| Cable Length: | Field-cuttable, subject to maximum circuit-length limits |
| Overlap Tolerance: | Designed to tolerate overlap without overheating or burnout, when installed according to manufacturer instructions |
| Braid Options: | Tinned copper or stainless steel, depending on configuration |
| Installation Environments: | Ordinary and specified hazardous (classified) locations, depending on cable construction and approvals |
| Certifications and Approvals: | FM and CSA approvals for specified configurations; verify the applicable model, area classification, and current documentation |
Important selection note: Heat output, maximum circuit length, startup current, voltage, and approvals vary by cable model and operating conditions. Confirm the manufacturer's current datasheet before specifying or purchasing a cable. The continuous maintenance temperature is not the same as the maximum intermittent exposure temperature.
Applications
2300 Series Industrial Self-Regulating Heating Cable Applications
The 2300 Series Industrial Self-Regulating Heating Cable is suited to industrial heat tracing applications that require dependable freeze protection or process temperature maintenance under demanding thermal conditions.
- Industrial pipe freeze protection: Helps prevent water and other compatible fluids from freezing in exposed or temperature-sensitive piping.
- Process temperature maintenance: Helps maintain the required temperature of fluids moving through industrial process lines.
- Fluid transport systems: Provides supplemental heat for piping carrying process fluids that must remain within a specified temperature range.
- Storage tanks and vessels: Helps reduce heat loss from compatible fluid storage equipment when properly engineered for the vessel and application.
- Steam-purge environments: Supports compatible systems that undergo specified saturated steam-purge procedures, subject to the manufacturer's temperature and pressure limitations.
- Chemical and process industries: Can be considered for suitable piping and equipment in chemical processing, refining, and other industrial facilities after verifying fluid compatibility, heat loss, and location requirements.
- Specified hazardous locations: Certain configurations may be used in classified areas when their certifications, construction, and installation meet the applicable requirements.
Correct cable selection depends on the required maintenance temperature, minimum ambient temperature, pipe or vessel dimensions, insulation, heat loss, supply voltage, circuit length, and installation environment. Valin can help customers evaluate these factors when selecting an industrial heat trace solution.
Q & A
2300 Series Industrial Self-Regulating Heating Cable Q & A:
Downloads
Download the 2300 Series Industrial Dekoron Self-Regulating Heating Cable Datasheet
Hands-On Assistance from Technical Specialists
Need help?
Fill out our heat trace application form and we will have one of our process heating experts contact you, or call (855) 737-4718 to speak to one of our experts immediately.